TAU cable

200 °C cable for...

measurement and analysis of physical sizes, medical, micro-electronics, instrumentation, resistant to flame (UL 94-V0), chemical agents, temperature...

Construction


Conductor
     - Silver plated soft copper core
     - PFA insulation (Perfluoro Alkoxy)
Twisting : 15 x Diameter
Silver plated soft copper braid
PFA Jacket (Perfluoro Alkoxy)

Characteristics


Service temperature : -196 / +200 °C
Chemical resistance : Excellent
Weathering resistance : Excellent
Flammability resistance : Excellent
European directive 2011/65 UE (RoHS2)
FDA agreements
UL rating : UL 94-V0

In White jacket

From 10 m


Reference

Outer
diameter

(mm)
Approx.
weight

(g/m)
36 AWG

TAU-3607.01
TAU-3607.02
TAU-3607.03
TAU-3607.04
TAU-3607.05
TAU-3607.06

TAU-3607.07
TAU-3607.08
TAU-3607.12


0.72
1.03
1.08
1.16
1.26
1.35
1.35
1.62
1.72

1.40
2.30
2.60
3.10
3.60
4.10
4.30
5.20
6.40

34 AWG

TAU-3407.03
TAU-3407.04

1.24
1.35

3.40
4.00

32 AWG TAU-3219.02
TAU-3219.03
TAU-3219.04

TAU-3219.05
TAU-3219.06
TAU-3219.07
TAU-3219.08
TAU-3219.12
1.43
1.51
1.64
1.79
1.94
1.94
2.36
2.53
3.90
4.70
5.70
6.70
7.60
8.30
9.90
12.80
Kfr =
N.n.d / 2.π.(∅ + 2.25.d).cos(α)

∅ : diameter under braid
d : ∅ of elementary braid wire
α : angle of braid with cable axis
N : number of carriers
n : number of wires per carrier

Coverage (%) = 2.Kfr - Kfr2

... Braid coverage

Shielding's efficiency is also characterized by braid coverage. Most of our cables have a coverage more than 85%, some of them may be increased to 92%, as coaxial cables. However, beyond 3 mm outer diameter, our tools of production do not allow us to meet this minimum value (contact us for more informations).